Dual Load Alternator and Alarm

Model PSA-1


Operation   Manual  

Applications  Ordering

Even the wear and increase the life of pumps in a dual pump and air conditioner systems.

The two control relays can be used to alternate between pumps, air conditioners, or any device you would like to even the wear on.

Alternate on time or on/off cycles

Multiple options to custom tune the control to your system.

If you need to know if your pumps are down, connect the PSA-1 alarm relay to an Input Guard and receive a phone call!

KEY FEATURES
Microprocessor controlled operation
Two load control relays
One Alarm Output Relay (dry contacts).  Connect the alarm relay contacts to an Input Guard and receive a phone call, "Warning pump is down!"
One Auxiliary Relay
Relay contact rating: 10a @ 277vac, 1.3hp @ 120vac, 24vdc coils
Automatic load verification "No Flow" alternation
Control On/Off input
Selectable no flow time delay and lead pump alternation
120:24vac supply voltage transformer included
NEMA-1 metal enclosure 12"x12"x4"

 

Description:

The PSA-1 Dual Load Sequencer is designed to even the wear of pumps, compressors, air conditioners, etc. in redundant systems. This manual will use the word load throughout this manual in place of pump, compressor, a/c, etc. The PSA-1 evens the wear on the loads by automatically alternating between the two loads based on running time or on-off cycles. The load that is energized first is referred to as the lead load, and the second load is referred to as the lag load. Pressing the A or B push-button selects the lead load.

The ON/OFF CONTROL input is used to energize a load. When the ON/OFF CONTROL input is closed, the lead load is energized. When the input is opened, the lead load is de-energized.

The PSA-1 monitors the FLOW input to verify operation of the load. When the lead load is energized, the PSA-1-1 will wait a selectable period of time. If after this period of time the FLOW input is not closed, indicating that the lead load is not functioning, the lead load is de-energized and the alarm relay is turned on. This load will no longer be energized and the lag load will become the new lead load.

A closure of the AUX input turns on the AUX OUTPUT relay. The user as required can utilize the AUX output relay.

The ALARM relay is energized when a load fails. Pressing the ALARM OFF button turns off the ALARM relay.

Pump A push-button selects pump A as lead pump.

Pump B push-button selects pump B as lead pump.

 

ORDERING INFORMATION
To order call toll free 1-888-248-7103
Quantity discounts available, resellers wanted!
Description Model Number List Price
Pump Sequencer PSA-1 $425.00 

 